THE VALUE OF MULTIPLEX REAL-TIME PCR IN THE IDENTIFICATION OF PATHOGENS IN CHILDREN WITH COMMUNITY-ACQUIRED PNEUMONIA AT HANOI MEDICAL UNIVERSITY HOSPITAL

Chau Tran Minh1, Hieu Vu Ngoc1, Hai To Thi2, Thu Nguyen Thi Minh1, Ngan Tran Thi2,
1 Bệnh viện Đại học Y Hà Nội; Trường Đại học Y Hà Nội
2 Bệnh viện Đại học Y Hà Nội

Author contact

Main Article Content

Abstract

Objectives: To identify the etiologies of community-acquired pneumonia in children using multiplex real-time PCR and to compare the detection rate of multiplex real-time PCR with bacterial culture.

Subjects and methods: A cross-sectional descriptive study was conducted on 342 children with community-acquired pneumonia at Hanoi Medical University Hospital.

Results: Multiplex real-time PCR detected viral infection in 26.0% of children, bacterial infection in 4.4%, viral-bacterial coinfection in 63.7%, and no pathogen in 5.8% of cases. The rate of viral-bacterial co-infection was high across all age groups and throughout all four seasons. The most common viruses were HRV (48.0%) and RSV (RSV A 20.8%, RSV B 9.1%), while the most common bacteria were H. influenzae (50.6%) and S. pneumoniae (43.0%). Multiplex real-time PCR increased pathogen detection compared to culture (94.2% vs. 60.8%).

Conclusion: Both bacterial culture and multiplex real-time PCR should be combined to diagnose the etiologies of community-acquired pneumonia in children.

Article Details